Last Modified: 11-29-2007 |
1.6 C |
|
Service Category: Brake |
Section: Brake Control/Dynamic Control System |
|
Model Year: 2008 |
Model: Sequoia |
Doc ID: RM000000OS901AX |
|
Title: BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS: VEHICLE STABILITY CONTROL SYSTEM: DESCRIPTION (2008 Sequoia) |
|
DTC
|
C0226/21
|
SFR Solenoid Circuit
|
|
DTC
|
C0236/22
|
SFL Solenoid Circuit
|
|
DTC
|
C0246/23
|
SRR Solenoid Circuit
|
|
DTC
|
C0256/24
|
SRL Solenoid Circuit
|
|
DTC
|
C1225/25
|
SMC Solenoid Circuit
|
|
DTC
|
C1226/26
|
SMC Solenoid Circuit
|
|
DTC
|
C1227/27
|
SRC Solenoid Circuit
|
|
DTC
|
C1228/28
|
SRC Solenoid Circuit
|
DESCRIPTION
This solenoid is turned on in accordance with signals from the skid control ECU and controls the pressure on the wheel cylinders to control the braking force.
|
DTC Code
|
DTC Detection Condition
|
Trouble Area
|
|
C0226/21
C0236/22
C0246/23
C0256/24
|
Open or short in solenoid circuit continues for 0.05 seconds or more.
|
VSC actuator (skid control ECU)
|
|
C1225/25
C1226/26
C122727
C1228/28
|
When any of following conditions detected:
-
During switching solenoid (SMC1, SMC2, SRC1 or SRC2) ON signal input, overcurrent continues for 0.05 seconds or more.
-
During switching solenoid (SMC1, SMC2, SRC1 or SRC2) OFF signal input, open circuit continues for 0.05 seconds or more.
-
During switching solenoid (SMC1, SMC2, SRC1 or SRC2) ON signal input, open circuit continues for 0.01 seconds or more.
-
During switching solenoid (SMC1, SMC2, SRC1 or SRC2) OFF signal input, current continues to be applied for 0.1 seconds or more.
-
Short to GND in switching solenoid (SMC1, SMC2, SRC1 or SRC2) continues for 0.1 seconds or more.
-
Switching solenoids (SMC1, SMC2, SRC1 or SRC2) shorted for 0.1 seconds or more.
|
VSC actuator (skid control ECU)
|
INSPECTION PROCEDURE
NOTICE:
When replacing the VSC actuator assembly, perform zero point calibration
.
PROCEDURE
(a) Clear the DTC(s)
.
(b) Start the engine.
(c) Check if the same DTC(s) is output
.
Result
|
Result
|
Proceed to
|
|
DTC is output
|
A
|
|
DTC is not output
|
B
|
HINT:
The DTCs may be stored due to a malfunction in the connector terminal.
| A |
|
|
|